Monday, April 25, 2011

[MW:10836] RE: Inconel 625 overlay on AISI4140

What is you code of construction, was there any lethal or sour service requirements? Hardness restrictions? Requirement of SCC etc.

What is the tempering temperature of the base material (probably 540 °C is recommended as it should not exceed the tempering temperature), refer the datasheet tempering temperature for this material in the range of 540-680°C

 

From: venu moturu [mailto:moturuvenu@yahoo.com]
Sent: Sunday, April 24, 2011 10:57 AM
To: materials-welding@googlegroups.com
Cc: Bathula Raghuram (Mumbai - PIPING)
Subject: Inconel 625 overlay on AISI4140

 

Dear Friends,

 

Could anyone  pl. advice or guide us  as we wanted to weld corrosion resistant overlay of Inconel 625 on AISI 4140 on a used sub sea equipment in the oil and gas sector , where in the application demands severe Tensile and cyclic loads  on the component . The overlay shall be of approximately 4~5mm on a 100 mm thick section .

 

The vendor has submitted us two procedures with pulsed GMAW (Auto ) welding process having with and without  PWHT . When we referred the procedure with PWHT  we found that  the procedure is qualified (at  540 degreeC @ soaking time 2hrs and rate of heating 150 degree C/Hr)

 

can anyone help me out to send the literature with and without PWHT

 

Best regards

venu

 

 



 


No comments:

[MW:34820] RE: 34813] Clarification in Rate of heating and cooling.

Hello,   Please see the response below.   Regards.   P. Goswami, P. Eng, IWE.   From: materials-welding@googlegroups.com <materials-weld...