Yes,
I think you are refring to same supporting PQR only for the both thickness ranges.
For E.g, If you have qualified a PQR with a thk of 8 mm with impact test.
Your qualification ranges in the WPS will be
8 to 16 mm (WIth Impact test)
5 to 16 mm (Without Impact test)
You can write both the reading in the WPS.
Hope this will clarify.
Cheers!
Raj
On Thu, Apr 14, 2011 at 7:57 AM, Ali Asghari <asghariali@rocketmail.com> wrote:
--Dear all
Is it possible a WPS issued that have two qualified thickness ranges?( one of them supported by a PQR that impact tested and another range with ignorance of the CVN results acc to ASME IX)
Regards.
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.